Canscope-800 – is advanced newly developed modular microscopy platform for research and diagnostic laboratory environment. The main features are wide 22 mm. Field of View, Infinity Corrected Optical system, Kohler illumination, stable integral structure and reasonable ergonomic design providing comfortable and effective operation.
Due to modular design and variety of designated attachments and accessories CN-800 appears to be a perfect instrument for observation in Bright Field mode as well as in Dark Field, Phase Contrast, polarized light and epi-fluorescence.
Ensuring image analysis and documentation process Canscope provides selection of advanced digital cameras for all modes of observation including low illumination Dark Field and Epi-Fluorescence modes. In addition Canscope offers advanced research grade multifunctional imaging software.
With large operational space, variety of modular mechanical bridges, Narishige micromanipulators, attachable stage incubators, perfusion systems and other third party components as well as sophisticated digital cameras and image processing software, CN-800 becomes an extremely cost efficient and reliable platform for university research.
With designated FL-800 epi-fluorescent attachment incorporating 6 revolving filter blocks and unlimited selection of fluorescent filters CN-800 microscope turns into an extremely useful instrument for medical diagnostic laboratory in fields of bacteriology, histology, immunology and pharmacology.
Main features:
Multi-coated Infinity corrected optics
Adjustable Kohler Illumination
Extra wide 22 mm. field of view
Compensation free Siedentopf type Binocular or Trinocular head, 300 inclined, suitable for every observer with wide interpupillary distance 48-75mm
lnverse Quintuple Nosepiece
Ultra easy “flying” stage to ensure prolonged hours of strain free operation
Perfect image with Infinity Corrected Plan Achromatic Objectives
Coaxial Coarse and Fine Focus knobs for comfortable operation with minimal increment 2 microns
Swing type condenser N.A. 0.9 / 0.25 aiming to overcome illumination asymmetry at low magnification
Dark Field attachments for dry and oil type observations
Phase Contrast attachment with Plan Phase contrast objectives and turret condenser
Polarized Light Observation with simple polarization kit
100 watt epi-fluorescent attachment with unlimited variety of filter block for any application
Variety of mechanical bridge type platforms, stage incubators, micromanipulators, micropipettes and other accessories available to build customized systems for electrophysiological and other research
Variety of digital cameras including scientific cameras for Dark field, Phase Contrast and Fluorescence micrography
Research grade multi functional Image Processing software available
Halogen 30 watt illumination
Optional 50 watt halogen illuminator, recommended for Phase Contrast and Dark Field modes
Multi-viewing teaching attachment with brightness adjustable green LED Pointer for 3 or 5 viewers.
Eyepiece
Nosepiece
Larger viewing area with rextra wide field eyepiece EW 10×/22. Focus control with Diopter adjustable.
Big operating space with backward quintuple nosepiece.
Objective
Stage
Perfect Image with Infinite Plan Achromatic Objective.
Rectangle Double Layers Mechanical Stage 185×142mm, Moving Range 75×55mm.
Comfortable Operation with Low Position Adjustable Knobs.
Field Diaphragm
Illuminator
With Aspherical Condenser and Kohler Illumination, Providing Enough, Even and High Contrast illumination for various Objective Observations.
Focusing Range 60 mm. with minimal increment 2 microns
Course Focusing Knob is tension adjustable for convenient operation
Upper focusing limit protection mechanism to prevent occasional damage to objectives.
Standard outfit
Optional Accessories
Objective Infinite Plan Achromatic Objective 20×
$60.00
Eyepieces Wide Field Eyepiece WF10X With 0.1Micrometer
$42.00
Viewing Head Compensation Free Trinocular Head, Siedentopf type, Inclined at 30 deg. 360 deg. rotatable
$850.00
Photo Attachement
$190.00
Video Adaptor C-Mount 1×
$19.00
Video Adaptor C-Mount 0.5×
$75.00
Polarization Attachement
$81.00
Turret Phase Contrast Kit
$880.00
Dry Dark Field Attacment
$125.00
Temperature controlled stage
$410.00
Teaching attachment With Brightness Adjustable Green LED Pointer, for simultaneous observation of 3 or 5 viewers.
Call for the best price
Illumination upgrade to 12 volt 50 watt halogen illumination
Call for the best price
Microscope Images
Specimens Images
Please select one of the typical configurations or contact Canscope Product Specialist for defining a customized configuration especially for you.
List of configurations with pictures below…
High-end configuration
Special-1 phase contrast
Special-2 epi-fluorescence
Special-3 combined phase contrast and epi-fluorescence
1. Main stand
2. Infinite Plan achromatic objectives set
3. Quintuple nosepiece
4. Ergo binocular tube
5. HDCE-50B camera with adaptor, driver and imaging software
1. Main Stand
2. Infinite Plan Achromatic objectives set
3. Quintuple nosepiece
4. Trinocular tube
5. Turret phase contrast kit with infinite phase objectives
6. HDCE-10C camera with adaptor, driver and imaging software
1. Main Stand
2. Infinite Plan Achromatic objectives set
3. Quintuple nosepiece
4. Trinocular tube
5. FL-800 epi-fluorescence attachment with infinite fluorescence free objectives set with filter cubes UV, V, B and G
6. HDCE-10C camera with adaptor, driver and imaging software
1. Main Stand
2. Infinite Plan Achromatic objectives set
3. Quintuple nosepiece
4. Trinocular tube
5. Turret phase contrast kit with infinite phase objectives
6. FL-800 epi-fluorescence attachment with infinite fluorescence free objectives set with filter cubes UV, V, B and G
7. HDCE-10C camera with adaptor, driver and imaging software
$3,700.00
$2,990.00
$5,500.00
$6,450.00
Comments & Clients Review
Troubleshooting
Some problems will happen in the using of the microscope, you could solve them according the following list. If you cannot solve the problem after checking the entire list, please contact us for assistance.
*** Optical Part ***
PROBLEM
REASON FOR PROBLEM
SOLUTION
1.
Illumination is opening, but the field of view is dark.
The poor contact exists in the lamp house and the illumination system.
Ensure the contact pin and the lamp holder pin work well.
The lamp bulb spoils.
change a new bulb.
The brightness adjustment knob is set too dark
Adjust the knob in a proper position
No use the appointed lamp bulb
use the specified halogen Lamp 6V30W
2.
The edge of the field of view has shadow or the brightness is asymmetry
The nosepiece is not in the located position
Adjust it into the located position
The surface of the lamp become black
Change a new lamp bulb
The surface of the lens is moldy or has contaminant
Clean the lens
3.
Find dust and stain in the field of view
There are stains on the specimen
Change the specimen
There are stains on the eyepiece
Clean the eyepiece
4.
The image is defocus\low-resolution
The objective damage
Mend and correct the objective (send to factory for overhauling)
The lens of the objective and eyepiece is moldy or have contaminant
Do cleaning
The opening of Aperture diaphragm and field diaphragm is not proper, and too much astigmatism.
Change the opening of the aperture diaphragm and field diaphragm
Fine focus system is broken
Examine and repair the fine focus system (send to factory for overhauling)
The objective is not in the center of the light path
Turn the nosepiece to the located position
5.
The image focus surface incline (one side is clear and the other side is faint)
The illumination light incline serious
Adjust the filament position ,let the light distributing of the field of view become symmetrical and bright
The specimen don’t correctly place
Put the specimen on the right position
The nosepiece is not in the located position
Turn the nosepiece in the required position
6.
The eyes are uncomfortable, the left and right fields of view is not coincided
The interpupillar distance is not correct
Adjust the interpupillar distance correctly
The diopter is not right
Adjust the diopter according your sight
Can’t adapt to binocular observation
When look into the objective, do not stare at the specimen but at the whole field of view, or move the eyes away to see other things, then back into the objective